VE.Direct communication port
The VE.Direct port can be connected to:
• A computer (VE.Direct to USB interface cable needed)
• Apple and Android smartphones, tablets, MacBook’s and other devices
(VE.Direct Bluetooth Smart dongle needed)
Fully configurable:
• Low battery voltage alarm trip and reset levels
• Low battery voltage cut-off and restart levels
• Dynamic cut-off: load dependent cut-off level
• Output voltage 210 – 245V
• Frequency 50 Hz or 60 Hz
• ECO mode on/off and ECO mode sense level
Monitoring:
• In- and output voltage, % load and alarms
Proven reliability
- The full bridge plus toroidal transformer topology has proven its reliability over many years.
- The inverters are short circuit proof and protected against overheating, whether due to overload or
high ambient temperature.
High start-up power
- Needed to start loads such as power converters for LED lamps, halogen lamps or electric tools.
ECO mode
- When in ECO mode, the inverter will switch to standby when the load decreases below a preset
value (min load: 15W). Once in standby the inverter will switch on for a short period (adjustable,
default: every 2,5 seconds). If the load exceeds a preset level, the inverter will remain on
Remote on/off
- A remote on/off switch can be connected to a two pole connector, or between battery plus and the
left hand contact of the two pole connector.
To transfer the load to another AC source: the automatic transfer switch
- For our low power inverters we recommend our Filax Automatic Transfer Switch. The Filax features
a very short switchover time (less than 20 milliseconds) so that computers and other electronic
equipment will continue to operate without disruption.
DC connection with screw terminal
- No special tools needed for installation
Technical Specification
- 24 Volt
- Cont. power at 25°C (1) 800VA
- Cont. power at 25°C / 40°C 650 / 560W
- Peak power 1500W
- Output AC voltage / frequency (adjustable) 230VAC or 120VAC +/- 3% 50Hz or 60Hz +/- 0,1%
- Input voltage range 18.4 – 34v
- DC low shut down (adjustable) 18.6
- Dynamic (load dependent) DC low shut down (fully configurable)
- DC low restart and alarm (adjustable) 21.8
- Battery charged detect (adjustable) 28.0
- Max. efficiency 90%
- Zero-load power 7.0W
- Default zero-load power in ECO mode
- (default retry interval: 2,5 s, adjustable) 1
- ECO mode stop and start power setting Adjustable
- Protection (2) a – f
- Operating temperature range -40 to +65°C (fan assisted cooling) Derate 1,25% per °C above 40°C
- Humidity (non-condensing) max 95%
ENCLOSURE
- Material & Colour Steel chassis and plastic cover (blue Ral 5012)
- Battery-connection Screw terminals
- Maximum cable cross-section 25 10mm² /AWG4
- Standard AC outlets UK (BS 1363)
- Protection category IP 21
- Weight 7.4kg
- Dimensions (hxwxd, mm) 117 x 232 x 327
ACCESSORIES
- Remote on-off Yes
- Automatic transfer switch Filax
Reviews